Sentinel LCT8 Ultrasonic Custody Transfer Liquid Flow Meter

 

In industries where measurement stability is critical to reliability and performance, the Sentinel LCT8 delivers peace of mind performance. Used primarily to measure hydrocarbon liquids and water in critical use applications, Sentinel LCT8 uses eight ultrasonic paths to achieve stable, reliable measurement, even in turbulent flow conditions typical in midstream applications. The Sentinel LCT8 design provides a stratified field that cancels effect of swirl and disturbances caused by viscosity changes or installation effects.

Features and Benefits

 

Full performance in multi-viscous conditions

 

The Sentinel LCT8 is viscosity independent, using proprietary algorithms to reduce the effects of viscosity. No prover run or change of settings is required when viscosity changes. The meter retains its accuracy over the whole range between minimum and maximum viscosity, using only one calibration curve.

 

Superior design and easier installation

 

The Sentinel LCT8 incorporates the compact industrial design of the Sentinel LCT4, including a cast flow cell with no exposed buffers or cables. This allows for seamless integration into a pipeline or process requiring a smaller installation footprint and shorter upstream and downstream straight run lengths. Transducers are enclosed in explosion-proof housings, requiring less buffer between them and the fluid, resulting in better accuracy.

 

Actionable, intelligent data

 

For leak detection applications, diagnostic flow data from Sentinel LCT8 can help operators decide what is significant. Changes in pipe and fluid data, coupled with pressure drop, may be indicative of potential problems. Over time, this flow data can yield diagnostic volumes and information about different sized leaks, which can help determine a threshold for triggering an alarm. The more accurate the data, the more reliable the model to determine what is a real leak and what is a false alarm.

All the advantages of ultrasonic flow measurement

 

• No drifting or required periodic calibration

• No pressure drop

• No restriction in the pipe

• No moving parts and no filters or strainers to wear out

 

Applications

 

• Pipeline leak detection

• Liquid custody transfer measurement

• Allocation measurement

• Any critical liquid process measurement

sentinel lct8 ultrasonic

Head office

 

1 Adeola Odeku Street

South Atlantic Petroleum Towers

Victoria Island | Lagos | Nigeria

Tel: +234 1904 9589, +234 (0) 909 026 0055

Lagos Branch Office

 

15, Ogundana Street | Off Allen Avenue |

Ikeja | Lagos | Nigeria

Stay Connected With Us!

GCA Energy Staff Email

Access Email Service

Port Harcourt Branch Office

 

15 Emeyal Street

GRA Phase I

Port Harcourt, Rivers State, Nigeria

Tel: +234 8093906260